Journal of Speech and Hearing Research Vol.38 549-555 June 1995.
© American Speech-Language-Hearing Association

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrowCustom Print
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lichtman, S. W.
Right arrow Articles by King, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lichtman, S. W.
Right arrow Articles by King, M. L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Delicious   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Effect of a Tracheostomy Speaking Valve on Secretions, Arterial Oxygenation, and Olfaction

A Quantitative Evaluation

Steven W. Lichtman 1
Ingrid L. Birnbaum 2
Maria R. Sanfilippo 2
John T. Pellicone 1
William J. Damon 1

Marjorie L. King 1

1 Department of Internal Medicine, Helen Hayes Hospital, West Haverstraw, NY and Department of Medicine, College of Physicians and Surgeons, Columbia University New York, NY
2 Department of Speech and Hearing, Helen Hayes Hospital, West Haverstraw, NY

Tracheostomy speaking valves consist of a one-way valve that closes upon exhalation, causing a redirection of exhaled gas into the upper airway, thus allowing for the primary benefit of speech. The present study was undertaken to test various hypotheses concerning the secondary benefits of speaking valves. We hypothesized that use of a speaking valve will result in a decrease in accumulated secretions, an increase in arterial oxygenation and an improvement in olfactory function. A total of 8 tracheotomized patients met the following inclusion criteria: age>18; ability to tolerate wearing a speaking valve for at least 3 hours; no unstable medical conditions; no use of thrombolytic agents. While using the speaking valve patients accumulated fewer secretions (74.3 ± 63.6 vs. 122.8 ± 44.6 ml/day, p= 0.004, n= 7) and had improved olfactory function (accuracy= 28.4± 5.2 vs. 8.1 ± 2.9%, p = 0.02; and percent correct = 64.2 ± 2.6 vs. 50.0 ± 3.9%, p = 0.03, n = 6) than when off the speaking valve. No significant differences were found in 24-hour arterial oxygen saturation (pulse oximetry and ABG analysis respectively, n=7), arterial PO2, pH, PCO2,; HCO3, or 24-hour heart rate (n= 7). Thus, the present study found a significant decrease in secretions and improvements in olfaction when tracheotomized patients wore a speaking valve, but no difference in arterial oxygenation.

KEY WORDS: speaking valves, tracheostomy, communication, oxygenation, olfaction

Submitted on August 1, 1994
Accepted on November 28, 1994


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Delicious Delicious   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?